CDC Inspection Report: Odyssey of the Seas

Inspection Date: 2024-01-15 • Operator: Royal Caribbean International • Score: 94 / 100

Final Score 94 / 100
Evaluation Satisfactory
Deficiencies Cited 3
Points Deducted -6 pts

Inspection Findings Key Facts

  • Inspection was conducted on 2024-01-15, Monday, January 15, 2024 for vessel Odyssey of the Seas (IMO 9795737).
  • Operator on inspection date was Royal Caribbean International.
  • Inspection type was Periodic Routine.
  • Final inspection score was 94 out of 100 points (Satisfactory).
  • Passing threshold in force on inspection date was 86 points.
  • Total of 3 deficiency items were cited resulting in 6 deducted points.

Inspection Overview

Ship Name at Inspection Odyssey of the Seas
Operating Cruise Line Royal Caribbean International
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)

Cited Deficiency Items & Corrective Actions

VSP Operations Manual citations
-2 Points
VSP Inspector Citation:

Aft plunge pool chlorine analyzer indicated 1.9 ppm free chlorine. (Observed on Odyssey of the Seas inspection).

Cruise Line Corrective Action Statement:

"Chlorine doser adjusted and pool retested at 2.8 ppm."

-3 Points
VSP Inspector Citation:

Potable water sample tap cap missing lanyard chain. (Observed on Odyssey of the Seas inspection).

Cruise Line Corrective Action Statement:

"New sanitized tether chain installed."

-2 Points
VSP Inspector Citation:

Dishwashing conveyor in crew pantry reached 154 degrees Fahrenheit rinse cycle. (Observed on Odyssey of the Seas inspection).

Cruise Line Corrective Action Statement:

"Calibrated rinse booster thermostat to 165 degrees."