CDC Inspection Report: Spectrum of the Seas
Inspection Date: 2022-09-15 • Operator: Royal Caribbean International • Score: 92 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2022-09-15, Thursday, September 15, 2022 for vessel Spectrum of the Seas (IMO 9778856).
- Operator on inspection date was Royal Caribbean International.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsBunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Spectrum of the Seas).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Spectrum of the Seas).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."
Crew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on Spectrum of the Seas).
"Dispenser pump replaced and primed immediately."
Cooked turkey breast in carving holding well registered 133 degrees Fahrenheit. (Observed during CDC inspection on Spectrum of the Seas).
"Product reheated to 165 degrees and steam table well water level replenished."