CDC Inspection Report: MSC Preziosa

Inspection Date: 2025-10-18 • Operator: MSC Cruises • Score: 84 / 100

Final Score 84 / 100
Evaluation Non-Satisfactory
Deficiencies Cited 6
Points Deducted -16 pts

Inspection Findings Key Facts

  • Inspection was conducted on 2025-10-18, Saturday, October 18, 2025 for vessel MSC Preziosa (IMO 9559864).
  • Operator on inspection date was MSC Cruises.
  • Inspection type was Periodic Routine.
  • Final inspection score was 84 out of 100 points (Non-Satisfactory).
  • Passing threshold in force on inspection date was 86 points.
  • Total of 6 deficiency items were cited resulting in 16 deducted points.

Inspection Overview

Ship Name at Inspection MSC Preziosa
Operating Cruise Line MSC Cruises
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)

Cited Deficiency Items & Corrective Actions

VSP Operations Manual citations
-3 Points
VSP Inspector Citation:

Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."

-3 Points
VSP Inspector Citation:

Crew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"Dispenser pump replaced and primed immediately."

-3 Points
VSP Inspector Citation:

Cooked turkey breast in carving holding well registered 133 degrees Fahrenheit. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"Product reheated to 165 degrees and steam table well water level replenished."

-2 Points
VSP Inspector Citation:

Warewasher chemical test strips past container manufacturer expiration date. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"New sealed lot of test strips placed into active station."

-3 Points
VSP Inspector Citation:

Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"Air curtain powered on and interlock verified operational."

-2 Points
VSP Inspector Citation:

Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on MSC Preziosa).

Cruise Line Corrective Action Statement:

"Sanitized protective dust cap fitted and locked."

Primary CDC VSP Inspection Report (External Government Document) → Primary CDC Corrective Action Statement (External Government Document) →