CDC Inspection Report: Carnival Sunrise
Inspection Date: 2022-02-10 • Operator: Carnival Cruise Line • Score: 88 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2022-02-10, Thursday, February 10, 2022 for vessel Carnival Sunrise (IMO 9138850).
- Operator on inspection date was Carnival Cruise Line.
- Inspection type was Periodic Routine.
- Final inspection score was 88 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 6 deficiency items were cited resulting in 12 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsCrew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on Carnival Sunrise).
"Dispenser pump replaced and primed immediately."
Cooked turkey breast in carving holding well registered 133 degrees Fahrenheit. (Observed during CDC inspection on Carnival Sunrise).
"Product reheated to 165 degrees and steam table well water level replenished."
Warewasher chemical test strips past container manufacturer expiration date. (Observed during CDC inspection on Carnival Sunrise).
"New sealed lot of test strips placed into active station."
Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Carnival Sunrise).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Carnival Sunrise).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Carnival Sunrise).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."