CDC Inspection Report: Celestyal Discovery
Inspection Date: 2018-03-17 • Operator: Holland America Line • Score: 84 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2018-03-17, Saturday, March 17, 2018 for vessel Celestyal Discovery (IMO 9070060).
- Operator on inspection date was Holland America Line.
- Inspection type was Periodic Routine.
- Final inspection score was 84 out of 100 points (Non-Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 6 deficiency items were cited resulting in 16 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsCooked turkey breast in carving holding well registered 133 degrees Fahrenheit. (Observed during CDC inspection on Celestyal Discovery).
"Product reheated to 165 degrees and steam table well water level replenished."
Warewasher chemical test strips past container manufacturer expiration date. (Observed during CDC inspection on Celestyal Discovery).
"New sealed lot of test strips placed into active station."
Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Celestyal Discovery).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Celestyal Discovery).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Celestyal Discovery).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."
Crew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on Celestyal Discovery).
"Dispenser pump replaced and primed immediately."