CDC Inspection Report: AIDAperla
Inspection Date: 2024-11-05 • Operator: AIDA Cruises • Score: 92 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2024-11-05, Tuesday, November 5, 2024 for vessel AIDAperla (IMO 9633939).
- Operator on inspection date was AIDA Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsGalley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on AIDAperla).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on AIDAperla).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on AIDAperla).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."
Crew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on AIDAperla).
"Dispenser pump replaced and primed immediately."