CDC Inspection Report: Seven Seas Voyager
Inspection Date: 2018-03-17 • Operator: Regent Seven Seas Cruises • Score: 95 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2018-03-17, Saturday, March 17, 2018 for vessel Seven Seas Voyager (IMO 9247144).
- Operator on inspection date was Regent Seven Seas Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 95 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 3 deficiency items were cited resulting in 5 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsGalley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Seven Seas Voyager).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Seven Seas Voyager).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Seven Seas Voyager).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."