CDC Inspection Report: Westerdam
Inspection Date: 2019-05-14 • Operator: Holland America Line • Score: 92 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2019-05-14, Tuesday, May 14, 2019 for vessel Westerdam (IMO 9226891).
- Operator on inspection date was Holland America Line.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsGalley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Westerdam).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Westerdam).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Westerdam).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."
Crew mess handwashing sink soap dispenser pump jammed during meal service. (Observed during CDC inspection on Westerdam).
"Dispenser pump replaced and primed immediately."