CDC Inspection Report: Azamara Onward
Inspection Date: 2018-10-08 • Operator: Azamara • Score: 84 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2018-10-08, Monday, October 8, 2018 for vessel Azamara Onward (IMO 9187887).
- Operator on inspection date was Azamara.
- Inspection type was Periodic Routine.
- Final inspection score was 84 out of 100 points (Non-Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 6 deficiency items were cited resulting in 16 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsClinical isolation order documentation for symptomatic crew member lacked physician counter-signature. (Observed during CDC inspection on Azamara Onward).
"Chief Medical Officer counter-signed isolation log and implemented digital sign-off alert."
Reduced pressure principle backflow preventer on deck 4 laundry line due for annual recertification. (Observed during CDC inspection on Azamara Onward).
"Device tested certified and tagged by licensed marine backflow technician."
Cook assistant wearing cloth wristband during hot line food preparation. (Observed during CDC inspection on Azamara Onward).
"Jewelry removed and food hygiene protocol reinforced with crew."
Flight-type dishwasher final rinse water temperature registered 158 degrees Fahrenheit. (Observed during CDC inspection on Azamara Onward).
"Rinse boiler booster heating element adjusted to maintain 165 degrees."
Cutting board on salad preparation line showed heavy surface scoring. (Observed during CDC inspection on Azamara Onward).
"Board resurfaced and sanitized."
Cracked tile grout observed beneath deck 2 beverage dispensary drain trough. (Observed during CDC inspection on Azamara Onward).
"Area re-grouted with marine-grade antimicrobial epoxy."