Inspection Findings Key Facts
- Inspection was conducted on 2018-03-17, Saturday, March 17, 2018 for vessel Norwegian Sky (IMO 9177557).
- Operator on inspection date was Norwegian Cruise Line.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsWarewasher chemical test strips past container manufacturer expiration date. (Observed during CDC inspection on Norwegian Sky).
"New sealed lot of test strips placed into active station."
Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Norwegian Sky).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Norwegian Sky).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Norwegian Sky).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."