Inspection Date: 2026-02-14 • Operator: Windstar Cruises • Score: 92 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2026-02-14, Saturday, February 14, 2026 for vessel Wind Star (IMO 8420878).
- Operator on inspection date was Windstar Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsWarewasher chemical test strips past container manufacturer expiration date. (Observed during CDC inspection on Wind Star).
"New sealed lot of test strips placed into active station."
Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Wind Star).
"Air curtain powered on and interlock verified operational."
Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Wind Star).
"Sanitized protective dust cap fitted and locked."
Main Lido pool halogen residual measured 1.9 ppm during peak afternoon occupancy. (Observed during CDC inspection on Wind Star).
"Automated feeder dosing rate increased and pool re-verified at 2.6 ppm."