Item 5: Water Production and Disinfection
Proper halogenation and pH control during evaporative or reverse osmosis water generation.
Inspection Area Potable Water
Max Deduction -4 Points
5-Yr Citations 154
Points Deducted (5Y) -257 pts
Item 5 Key Facts
- VSP Operations Manual Item 5: Water Production and Disinfection (Potable Water).
- Maximum point deduction per citation is 4 points.
- Cited 154 times across fleet inspections over the five-year evaluation window.
- Total points deducted under this item across all inspections: 257 points.
- Coverage verified through 2026-09-17, Thursday, September 17, 2026.
Recorded Citations Across Fleet Inspections
Specific violations cited under Item 5| Vessel / Inspection | Date | Deduction | Citation Finding | Corrective Action Statement |
|---|---|---|---|---|
| Carnival Sunrise | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Sunrise). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Sunrise | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Sunrise). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Radiance | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Radiance). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Luminosa | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Luminosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Horizon | 2022-02-10 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Horizon). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Vista | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Vista). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Vista | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Vista). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Venezia | 2024-05-19 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Venezia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Firenze | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Firenze). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Firenze | 2022-09-15 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Firenze). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Icon of the Seas | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Icon of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Icon of the Seas | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Icon of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wonder of the Seas | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wonder of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Harmony of the Seas | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Harmony of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Harmony of the Seas | 2022-02-10 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Harmony of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Odyssey of the Seas | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Odyssey of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Ovation of the Seas | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Ovation of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Anthem of the Seas | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Anthem of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Viva | 2023-10-12 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Viva). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Viva | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Viva). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Encore | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Encore). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Bliss | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Bliss). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Joy | 2023-10-12 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Joy). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Joy | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Joy). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Escape | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Escape). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Disney Wish | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Disney Wish). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Disney Fantasy | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Disney Fantasy). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Disney Dream | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Disney Dream). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Disney Wonder | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Disney Wonder). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Disney Magic | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Disney Magic). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Apex | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Apex). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Edge | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Edge). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Sun Princess | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Sun Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Discovery Princess | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Discovery Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Discovery Princess | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Discovery Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Nieuw Statendam | 2024-05-19 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Nieuw Statendam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Koningsdam | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Koningsdam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Koningsdam | 2022-09-15 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Koningsdam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Seascape | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Seascape). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Meraviglia | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Meraviglia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Scarlet Lady | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Scarlet Lady). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Sea | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Sea). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Dream | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Dream). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Breeze | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Breeze). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Breeze | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Breeze). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Sunshine | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Sunshine). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Sunshine | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Sunshine). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Conquest | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Conquest). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Glory | 2021-10-04 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Glory). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Liberty | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Liberty). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Liberty | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Liberty). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Liberty | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Liberty). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Freedom | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Freedom). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Pride | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Pride). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Legend | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Legend). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Legend | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Legend). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Carnival Elation | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Carnival Elation). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Liberty of the Seas | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Liberty of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Explorer of the Seas | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Explorer of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Adventure of the Seas | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Adventure of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Navigator of the Seas | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Navigator of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Navigator of the Seas | 2018-03-17 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Navigator of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Mariner of the Seas | 2019-11-20 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Mariner of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Radiance of the Seas | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Radiance of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Brilliance of the Seas | 2023-10-12 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Brilliance of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Jewel of the Seas | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Jewel of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Grandeur of the Seas | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Grandeur of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Grandeur of the Seas | 2025-04-22 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Grandeur of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Rhapsody of the Seas | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Rhapsody of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Rhapsody of the Seas | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Rhapsody of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Vision of the Seas | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Vision of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Vision of the Seas | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Vision of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Vision of the Seas | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Vision of the Seas). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Breakaway | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Breakaway). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Getaway | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Getaway). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Jewel | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Jewel). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Jewel | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Jewel). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Gem | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Gem). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Dawn | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Dawn). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Sun | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Sun). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Sky | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Sky). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Sky | 2024-05-19 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Sky). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Spirit | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Norwegian Spirit | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Norwegian Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Star Princess | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Star Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Majestic Princess | 2018-03-17 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Majestic Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Regal Princess | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Regal Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Caribbean Princess | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Caribbean Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Crown Princess | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Crown Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Emerald Princess | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Emerald Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Ruby Princess | 2025-10-18 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Ruby Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Diamond Princess | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Diamond Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Grand Princess | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Grand Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Coral Princess | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Coral Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Coral Princess | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Coral Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Coral Princess | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Coral Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Island Princess | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Island Princess). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Silhouette | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Silhouette). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Solstice | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Solstice). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Constellation | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Constellation). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Constellation | 2018-10-08 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Constellation). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Infinity | 2021-10-04 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Infinity). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Summit | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Summit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Celebrity Millennium | 2019-11-20 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Celebrity Millennium). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Oosterdam | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Oosterdam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Oosterdam | 2018-03-17 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Oosterdam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Volendam | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Volendam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Zaandam | 2025-04-22 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Zaandam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Zaandam | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Zaandam). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC World Europa | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC World Europa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC World America | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC World America). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Virtuosa | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Virtuosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Virtuosa | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Virtuosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Bellissima | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Bellissima). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Seaview | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Seaview). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Preziosa | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Preziosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Splendida | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Splendida). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Magnifica | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Magnifica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Orchestra | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Orchestra). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| MSC Musica | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on MSC Musica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Resilient Lady | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Resilient Lady). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Sky | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Sky). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Sky | 2022-09-15 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Sky). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Orion | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Orion). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Jupiter | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Jupiter). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Jupiter | 2024-05-19 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Jupiter). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Neptune | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Neptune). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Neptune | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Neptune). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Marina | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Marina). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Riviera | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Riviera). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Insignia | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Insignia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Nautica | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Nautica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Nautica | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Nautica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Nautica | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Nautica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Nautica | 2018-03-17 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Nautica). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seven Seas Explorer | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seven Seas Explorer). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seven Seas Mariner | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seven Seas Mariner). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seven Seas Mariner | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seven Seas Mariner). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seven Seas Navigator | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seven Seas Navigator). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seven Seas Navigator | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seven Seas Navigator). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Ray | 2024-11-05 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Ray). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Dawn | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Dawn). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Moon | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Moon). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Spirit | 2024-05-19 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Spirit | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Shadow | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Shadow). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Shadow | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Shadow). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Silver Whisper | 2022-02-10 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Silver Whisper). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Queen Mary 2 | 2023-10-12 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Queen Mary 2). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Queen Mary 2 | 2018-03-17 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Queen Mary 2). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Queen Victoria | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Queen Victoria). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Queen Elizabeth | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Queen Elizabeth). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Queen Elizabeth | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Queen Elizabeth). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Azamara Pursuit | 2021-10-04 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Azamara Pursuit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Azamara Journey | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Azamara Journey). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Azamara Journey | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Azamara Journey). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Azamara Quest | 2022-02-10 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Azamara Quest). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Margaritaville at Sea Paradise | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Margaritaville at Sea Paradise). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Margaritaville at Sea Islander | 2021-10-04 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Margaritaville at Sea Islander). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Toscana | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Toscana). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Smeralda | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Smeralda). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Smeralda | 2022-09-15 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Smeralda). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Diadema | 2023-10-12 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Diadema). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Favolosa | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Favolosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Favolosa | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Favolosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Deliziosa | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Deliziosa). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Costa Fortuna | 2019-05-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Costa Fortuna). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seabourn Venture | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seabourn Venture). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seabourn Ovation | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seabourn Ovation). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seabourn Quest | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seabourn Quest). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seabourn Sojourn | 2019-11-20 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seabourn Sojourn). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Seabourn Sojourn | 2019-05-14 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Seabourn Sojourn). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Star Breeze | 2019-05-14 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Star Breeze). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Star Legend | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Star Legend). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wind Surf | 2026-02-14 | -3 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wind Surf). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wind Surf | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wind Surf). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wind Star | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wind Star). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wind Spirit | 2022-02-10 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wind Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Wind Spirit | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Wind Spirit). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Iona | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Iona). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Iona | 2023-10-12 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Iona). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Britannia | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Britannia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Britannia | 2021-10-04 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Britannia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Britannia | 2019-11-20 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Britannia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Azura | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Azura). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Ventura | 2018-03-17 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Ventura). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Aurora | 2025-10-18 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Aurora). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Arcadia | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Arcadia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Arcadia | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Arcadia). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAnova | 2019-05-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAnova). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAcosma | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAcosma). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAprima | 2025-04-22 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAprima). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAprima | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAprima). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAperla | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAperla). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAperla | 2018-03-17 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAperla). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAmar | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAmar). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| AIDAmar | 2023-10-12 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on AIDAmar). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Octantis | 2025-04-22 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Octantis). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Polaris | 2023-03-28 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Polaris). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Viking Polaris | 2022-02-10 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Viking Polaris). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Bolette | 2018-10-08 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Bolette). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Borealis | 2018-10-08 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Borealis). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Balmoral | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Balmoral). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Roald Amundsen | 2026-02-14 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Roald Amundsen). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Roald Amundsen | 2021-10-04 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Roald Amundsen). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Fridtjof Nansen | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Fridtjof Nansen). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Spitsbergen | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Spitsbergen). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Le Commandant Charcot | 2025-10-18 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Le Commandant Charcot). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Le Dumont-d-Urville | 2024-11-05 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Le Dumont-d-Urville). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Le Champlain | 2024-05-19 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Le Champlain). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| Le Laperouse | 2026-02-14 | -1 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on Le Laperouse). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| World Navigator | 2023-03-28 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on World Navigator). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
| World Navigator | 2022-09-15 | -2 | Reverse osmosis permeate halogen analyzer chart recorded 1.8 ppm free chlorine at 0400 hours. (Observed during CDC inspection on World Navigator). | Chlorine doser pump recalibrated to maintain 2.2 ppm target residual. |
Advertisement Space (ad-after-table)