CDC Inspection Report: Iona

Inspection Date: 2026-02-14 • Operator: P&O Cruises • Score: 97 / 100

Final Score 97 / 100
Evaluation Satisfactory
Deficiencies Cited 2
Points Deducted -3 pts

Inspection Findings Key Facts

  • Inspection was conducted on 2026-02-14, Saturday, February 14, 2026 for vessel Iona (IMO 9826548).
  • Operator on inspection date was P&O Cruises.
  • Inspection type was Periodic Routine.
  • Final inspection score was 97 out of 100 points (Satisfactory).
  • Passing threshold in force on inspection date was 86 points.
  • Total of 2 deficiency items were cited resulting in 3 deducted points.

Inspection Overview

Ship Name at Inspection Iona
Operating Cruise Line P&O Cruises
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)

Cited Deficiency Items & Corrective Actions

VSP Operations Manual citations
-2 Points
VSP Inspector Citation:

Galley waste air curtain fan switch turned off during evening cleaning shift. (Observed during CDC inspection on Iona).

Cruise Line Corrective Action Statement:

"Air curtain powered on and interlock verified operational."

-1 Points
VSP Inspector Citation:

Bunkering hose connection fitting in starboard manifold lacked dust cap during storage. (Observed during CDC inspection on Iona).

Cruise Line Corrective Action Statement:

"Sanitized protective dust cap fitted and locked."

Primary CDC VSP Inspection Report (External Government Document) → Primary CDC Corrective Action Statement (External Government Document) →