CDC Inspection Report: Seven Seas Splendor
Inspection Date: 2024-05-19 • Operator: Regent Seven Seas Cruises • Score: 97 / 100
Final Score 97 / 100
Evaluation Satisfactory
Deficiencies Cited 2
Points Deducted -3 pts
Inspection Findings Key Facts
- Inspection was conducted on 2024-05-19, Sunday, May 19, 2024 for vessel Seven Seas Splendor (IMO 9807085).
- Operator on inspection date was Regent Seven Seas Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 97 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 2 deficiency items were cited resulting in 3 deducted points.
Inspection Overview
Ship Name at Inspection Seven Seas Splendor
IMO Entity Key 9807085 (View Ship Dossier →)
Operating Cruise Line Regent Seven Seas Cruises
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citations
VSP Inspector Citation:
Reheating temperature digital thermocouple calibration was 2 degrees off ice point. (Observed during CDC inspection on Seven Seas Splendor).
Cruise Line Corrective Action Statement:
"Thermometer recalibrated against certified reference thermometer."
VSP Inspector Citation:
Waste management pulper room deck drain screen missing retention bolt. (Observed during CDC inspection on Seven Seas Splendor).
Cruise Line Corrective Action Statement:
"Stainless steel retention fastener installed."