CDC Inspection Report: Viking Orion
Inspection Date: 2022-02-10 • Operator: Viking Ocean Cruises • Score: 88 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2022-02-10, Thursday, February 10, 2022 for vessel Viking Orion (IMO 9796250).
- Operator on inspection date was Viking Ocean Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 88 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 6 deficiency items were cited resulting in 12 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsPotable water sample tap on deck 2 forward distribution loop lacked proper sanitary sampling collar. (Observed during CDC inspection on Viking Orion).
"New sanitized sampling collar installed."
Aft whirlpool spa continuous pH recorder ran out of chart paper for 45 minutes. (Observed during CDC inspection on Viking Orion).
"Chart paper replaced recorder verified and hourly manual log verified compliant."
Shellfish identification tags for 2 sacks of oysters lacked 90-day chronologic sorting binder. (Observed during CDC inspection on Viking Orion).
"Tags indexed chronologically in compliance with USPH standard."
Deep container used for cooling chili instead of shallow 2-inch stainless steel pan. (Observed during CDC inspection on Viking Orion).
"Chili transferred to shallow pans with ice bath paddles."
Light grease buildup observed on auxiliary grill exhaust hood baffle filters. (Observed during CDC inspection on Viking Orion).
"Hood filters removed and processed through high-temperature dishwasher."
Youth center sanitized toy bins lacked date rotation tag. (Observed during CDC inspection on Viking Orion).
"Tags applied and toy rotation protocol documented."