CDC Inspection Report: Costa Smeralda

Inspection Date: 2026-02-14 • Operator: Costa Cruises • Score: 95 / 100

Final Score 95 / 100
Evaluation Satisfactory
Deficiencies Cited 3
Points Deducted -5 pts

Inspection Findings Key Facts

  • Inspection was conducted on 2026-02-14, Saturday, February 14, 2026 for vessel Costa Smeralda (IMO 9781865).
  • Operator on inspection date was Costa Cruises.
  • Inspection type was Periodic Routine.
  • Final inspection score was 95 out of 100 points (Satisfactory).
  • Passing threshold in force on inspection date was 86 points.
  • Total of 3 deficiency items were cited resulting in 5 deducted points.

Inspection Overview

Ship Name at Inspection Costa Smeralda
Operating Cruise Line Costa Cruises
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)

Cited Deficiency Items & Corrective Actions

VSP Operations Manual citations
-2 Points
VSP Inspector Citation:

Reheating temperature digital thermocouple calibration was 2 degrees off ice point. (Observed during CDC inspection on Costa Smeralda).

Cruise Line Corrective Action Statement:

"Thermometer recalibrated against certified reference thermometer."

-2 Points
VSP Inspector Citation:

Waste management pulper room deck drain screen missing retention bolt. (Observed during CDC inspection on Costa Smeralda).

Cruise Line Corrective Action Statement:

"Stainless steel retention fastener installed."

-1 Points
VSP Inspector Citation:

Gastrointestinal illness 24-hour log had 1 entry missing symptom onset timestamp. (Observed during CDC inspection on Costa Smeralda).

Cruise Line Corrective Action Statement:

"Medical staff reviewed logging protocol and rectified time verification procedures."

Primary CDC VSP Inspection Report (External Government Document) → Primary CDC Corrective Action Statement (External Government Document) →