CDC Inspection Report: MSC Seaview
Inspection Date: 2018-10-08 • Operator: MSC Cruises • Score: 92 / 100
Inspection Findings Key Facts
- Inspection was conducted on 2018-10-08, Monday, October 8, 2018 for vessel MSC Seaview (IMO 9745378).
- Operator on inspection date was MSC Cruises.
- Inspection type was Periodic Routine.
- Final inspection score was 92 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 4 deficiency items were cited resulting in 8 deducted points.
Inspection Overview
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citationsYouth center sanitized toy bins lacked date rotation tag. (Observed during CDC inspection on MSC Seaview).
"Tags applied and toy rotation protocol documented."
Potable water sample tap on deck 2 forward distribution loop lacked proper sanitary sampling collar. (Observed during CDC inspection on MSC Seaview).
"New sanitized sampling collar installed."
Aft whirlpool spa continuous pH recorder ran out of chart paper for 45 minutes. (Observed during CDC inspection on MSC Seaview).
"Chart paper replaced recorder verified and hourly manual log verified compliant."
Shellfish identification tags for 2 sacks of oysters lacked 90-day chronologic sorting binder. (Observed during CDC inspection on MSC Seaview).
"Tags indexed chronologically in compliance with USPH standard."