CDC Inspection Report: Nieuw Amsterdam
Inspection Date: 2019-05-14 • Operator: Holland America Line • Score: 97 / 100
Final Score 97 / 100
Evaluation Satisfactory
Deficiencies Cited 2
Points Deducted -3 pts
Inspection Findings Key Facts
- Inspection was conducted on 2019-05-14, Tuesday, May 14, 2019 for vessel Nieuw Amsterdam (IMO 9437866).
- Operator on inspection date was Holland America Line.
- Inspection type was Periodic Routine.
- Final inspection score was 97 out of 100 points (Satisfactory).
- Passing threshold in force on inspection date was 86 points.
- Total of 2 deficiency items were cited resulting in 3 deducted points.
Inspection Overview
Ship Name at Inspection Nieuw Amsterdam
IMO Entity Key 9437866 (View Ship Dossier →)
Operating Cruise Line Holland America Line
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)
Cited Deficiency Items & Corrective Actions
VSP Operations Manual citations
VSP Inspector Citation:
Potable water sample tap on deck 2 forward distribution loop lacked proper sanitary sampling collar. (Observed during CDC inspection on Nieuw Amsterdam).
Cruise Line Corrective Action Statement:
"New sanitized sampling collar installed."
VSP Inspector Citation:
Aft whirlpool spa continuous pH recorder ran out of chart paper for 45 minutes. (Observed during CDC inspection on Nieuw Amsterdam).
Cruise Line Corrective Action Statement:
"Chart paper replaced recorder verified and hourly manual log verified compliant."