CDC Inspection Report: Wind Spirit

Inspection Date: 2024-11-05 • Operator: Windstar Cruises • Score: 97 / 100

Final Score 97 / 100
Evaluation Satisfactory
Deficiencies Cited 2
Points Deducted -3 pts

Inspection Findings Key Facts

  • Inspection was conducted on 2024-11-05, Tuesday, November 5, 2024 for vessel Wind Spirit (IMO 8611116).
  • Operator on inspection date was Windstar Cruises.
  • Inspection type was Periodic Routine.
  • Final inspection score was 97 out of 100 points (Satisfactory).
  • Passing threshold in force on inspection date was 86 points.
  • Total of 2 deficiency items were cited resulting in 3 deducted points.

Inspection Overview

Ship Name at Inspection Wind Spirit
Operating Cruise Line Windstar Cruises
Inspection Type Periodic Routine
Advertisement Space (ad-after-table)

Cited Deficiency Items & Corrective Actions

VSP Operations Manual citations
-2 Points
VSP Inspector Citation:

Waste management pulper room deck drain screen missing retention bolt. (Observed during CDC inspection on Wind Spirit).

Cruise Line Corrective Action Statement:

"Stainless steel retention fastener installed."

-1 Points
VSP Inspector Citation:

Gastrointestinal illness 24-hour log had 1 entry missing symptom onset timestamp. (Observed during CDC inspection on Wind Spirit).

Cruise Line Corrective Action Statement:

"Medical staff reviewed logging protocol and rectified time verification procedures."

Primary CDC VSP Inspection Report (External Government Document) → Primary CDC Corrective Action Statement (External Government Document) →